Quality Assurance Program
SECTION 1: MILL ORDER REVIEW A. Upon receipt of customer's purchase order, it will be transferred to an Tridipanel System sales order form by the sales department. B. Special care will be taken to verify:
C. After review and scheduling of production, the customer will be advised concerning delivery. SECTION 2: RAW MATERIALS A. Specification to suppliers 1. Welded Mesh: All suppliers of welded mesh will be informed in writing that 100% of the product delivered to Tridipanel System shall meet American Society of Testing Materials (ASTM) Specification A-185. In addition, suppliers will be charged with supplying mesh that conforms to "Specifications for Tridipanel System 3 - D Panel Building System" sheet. 2. Polystyrene: The polystyrene foam core shall have a minimum density of 0.9 pounds per cubic foot and shall comply with ASTM Specification C578-07a. Suppliers will have the following information printed on each panel:
The panels are to be delivered straight and damage free.
3. Gavanized Wire: All galvanized wire used in the manufacture of the 3 - D panels will conform to ASTM A82.
SECTION III - PRODUCTION PROCEDURES A. Prepartory Inspection: After mesh coils are mounted on the uncoiler mandrels, the first six feet of the coil will be measured to determine if spacing is within limits. Likewise, as polystrene panels are unpacked and loaded into the entry magazine, they will be examined for defects (cracks or gouges). Wire will be inspected in a similar manner as it is rewound onto spools. Observations here will focus on the quality and continuity of the zinc coating. Any quality problems detected will be reported at once to the supervisor. B. Manufacturing Controls: It is the responsibility of the operating crew and supervisor to monitor all phases of production activity to insure that only quality product is being is being produced. Any equipment producing unacceptable product is to be stopped immediately and the necessary action taken to remedy the source of the trouble. Any products produced that fail to meet the quality standards are to be removed to the reject area at once.
SECTION IV - RECONDITIONING STATION RESPONSIBILITY Besides the items listed below, workers in this area are charged to see that panels leaving the station are in overall prime condition including no bent wires and the correct identification is securely attached. A. Staywire: Occasionally staywires are missing. They must be replaced with straight lengths of the proper gauge wire secured within 1/2" of the position of the original wire. B. Welds and broken
wires: Welds can be successfully be repaired using the Miller WT 2530
Spot Welder. Caution will be exercised to see that the proper heat setting
and compression is achieved. Broken wires can be successfully repaired
using another short piece of the same gauge wire welded adjacent to the
break.
SECTION V - PACKAGING AND LOADING Loading instructions are typically received at the time the order is taken. Special packaging and shipping instructions are included on the mill order. Due to the light weight of the product, every effort will be made by the plant to insure loading is conducted in such a manner so as to maximize the effecient use of space. Panels will be stretch-wrapped and/or tarped according to the customers wishes. (Tridipanel System can not insure that damage will not incur to a covering tarp during transit.) On a flatbed truck, bands will be attached to the bundles of panels in such a manner as to prevent damage. Sufficient blocking lumber to secure the load along with instructions and assistance will be provided to all truckers.
Telephone (760) 643-2303, Fax (760) 295-9828 or E-Mail us.
|